The Water Heater Guide

Maintenance

Water Heater Maintenance: A Yearly Checklist That Extends Its Life

Updated November 19, 2026By the The Water Heater Guide editorial team
Water Heater Maintenance

Water heater maintenance is a yearly routine that keeps the tank clean, the safety valves working and the burner or heating elements efficient. Flush sediment, inspect the anode rod, test the temperature and pressure relief valve, set the thermostat to 120°F, check gas venting, and confirm insulation and the drain pan. Regular upkeep helps the unit reach its expected life.

Why water heater maintenance pays off

According to the U.S. Department of Energy (DOE), water heating is about 18% of a home's energy use. Sediment that settles in a tank forces the burner or element to work harder, which wastes energy and can shorten the life of the tank. Anode rods, valves and burners also age, and a short check each year catches small problems before they become leaks or no-hot-water calls.

DOE reports that most storage (tank) water heaters last 10 to 15 years, while tankless water heaters can last more than 20 years. Maintenance will not guarantee either number, but it helps your unit stay in that range. Many manufacturers recommend flushing at least once a year, and the manual for your model sets the exact intervals for flushing, anode checks and descaling.

Safety first

Before you open any cover on an electric unit, turn off its breaker and use a voltage tester to confirm there is no power. On a gas unit, if you smell gas, leave the home right away and call the gas utility or 911 from outside. Do not operate light switches, appliances or phones inside the home.

The yearly checklist in order

  1. Confirm the thermostat is set to 120°F and check the actual hot water temperature at a tap.
  2. Test the temperature and pressure (T&P) relief valve and confirm its discharge pipe is correct.
  3. Flush the tank to remove sediment (tank units).
  4. Inspect the anode rod (tank units with one).
  5. Check venting and the burner (gas units).
  6. Check the insulation, pipe wrap and drain pan.
  7. Write the results in a maintenance log.

Set the temperature to 120°F

DOE describes 120°F as a temperature considered safe for most of the population, and the U.S. Consumer Product Safety Commission (CPSC) also recommends setting water heaters to 120°F. According to CPSC, third-degree burns can occur after about 2 seconds at 150°F, about 6 seconds at 140°F and about 30 seconds at 130°F, and they can occur after 5 minutes at 120°F. Lowering the setting reduces scald risk at every tap.

To check the real temperature, run the hot tap at a sink until the reading settles, then measure the water with a cooking or instant-read thermometer. Adjust the thermostat if the reading is well off the setting, and recheck after a day. Note that the dial on many units is only a rough guide.

DOE notes that people with a compromised immune system or chronic respiratory disease may want to keep the tank at 140°F to limit Legionella growth. DOE's Federal Energy Management Program (FEMP) notes that Legionella can grow in water heaters under certain conditions. A tempering (mixing) valve set to 120°F, installed downstream of the tank, lets the tank run hotter without adding scald risk at the tap.

Flush the tank to remove sediment

Minerals from hard water settle on the bottom of a tank. This layer insulates the water from the heat source, so the unit runs longer and heats less efficiently. Flushing removes much of the loose sediment.

  1. Turn off power at the breaker for an electric unit, or set the gas control to the off or pilot position for a gas unit, as the manual directs.
  2. Close the cold water supply valve to the heater.
  3. Attach a hose to the drain valve at the bottom of the tank and route the other end to a floor drain or an outdoor spot that can handle hot water.
  4. Open a hot tap somewhere in the house so air can enter the tank and the water can drain.
  5. Open the drain valve and let the tank empty. Open the cold supply briefly to stir up remaining sediment, then drain again until the water runs clear.
  6. Close the drain valve, remove the hose, close the hot tap, open the cold supply, and let the tank refill fully before restoring power or gas.

Never restore power to an electric element while the tank is empty. If the drain valve is clogged, leaks, or the tank is heavily scaled, stop and have a pro look at it.

Inspect the anode rod

The anode rod is a sacrificial metal rod screwed into the top of many tank heaters. It corrodes so the steel tank lining does not. Check the rod according to the manual, because some units have no anode and some use a powered version that needs different care.

  • Turn off power or gas, close the cold supply, and open a hot tap to relieve pressure.
  • Place a socket on the hex head of the rod and unscrew it. Some rods are long, so check for enough clearance above the tank.
  • Look for a thin rod, pitting, or bare core wire. A rod that is mostly consumed should be replaced.
  • Use thread sealant if the manual calls for it, and tighten the rod firmly before refilling.

If the rod is seized in the fitting, do not force it, because the fitting can crack. A pro can free or replace it safely.

Test the temperature and pressure relief valve

The T&P valve is the safety outlet that opens if the temperature or pressure inside the tank gets too high. Test it once a year.

  1. Place a bucket under the discharge pipe and stand to the side of the valve.
  2. Lift the test lever gently, hold it briefly, then let it snap back into place.
  3. Water should flow for a few seconds and then stop cleanly. If it does not flow, or it keeps dripping after you release the lever, turn off the heater and have the valve replaced.

Never cap, plug or remove a T&P valve, and never add a valve or fitting to its discharge line. A valve that is blocked is no longer protecting the tank.

Check the discharge pipe

The discharge pipe carries released water away from the valve. The 2021 editions of the International Plumbing Code (section 504.6) and the International Residential Code (section P2804.6.1), as summarized by the International Code Council, set these requirements:

  • No direct connection to the drainage system.
  • The pipe ends in an air gap in the same room as the heater.
  • The pipe is not smaller than the valve outlet and is not trapped.
  • It drains by gravity and ends no more than 6 inches above the floor or a waste receptor.
  • No threaded end, valves or tees on the line.
  • The valve and piping are rated for 100 psi at 180°F.

Adoption of these codes varies by state and city, so check with your local building department for the rules that apply to your home.

Venting and burner check on gas units

A gas water heater sends combustion gases up a flue. A blocked or leaking vent can let carbon monoxide enter the living space. Look at the vent connector and flue for rust, separated joints, sagging or gaps. Confirm that the vent slopes upward toward the chimney or outdoor termination, and that nothing blocks the draft hood or the combustion air openings.

With the burner lit, look through the sight glass or access door if your unit has one. The flame should be steady and mostly blue, and there should be no soot on the burner or draft hood. A yellow or flickering flame, soot, or a strong odor after the unit runs means it needs a professional inspection before you use it again.

CPSC recommends carbon monoxide alarms on every level of the home and outside sleeping areas. Test the alarms during your yearly routine and replace them when the manufacturer's date or end-of-life signal says to.

Insulation, pipe wrap and the drain pan

Check the outer jacket of the tank for tears, loose insulation or damp spots. A simple insulation blanket can help older tanks, but cover only the sides of the tank as the manual allows. Keep it away from the top, the controls, the burner access and the vent.

Insulated pipe sleeves on the first few feet of hot and cold lines reduce heat loss and help the water arrive hotter. Replace sleeves that are wet, torn or crumbling.

If the heater sits in a closet, attic, garage or over a finished floor, a drain pan with a drain line can catch a slow leak before it damages the floor or ceiling below. Each year, look inside the pan for water, rust or sediment, make sure the drain line is clear, and confirm it drains to a spot you can see. Check with your local building department for pan and drain requirements, since they vary.

Tank and tankless maintenance compared

Both tank and tankless units need checks, but the tasks differ. The federal test procedure rates storage tanks by First-Hour Rating, the estimate of hot water a tank can supply in an hour starting fully heated, and tankless units by Maximum GPM, the most gallons per minute they can supply. Use the manual to find the descaling, filter and valve steps for your model.

TaskStorage tankTankless
Flushing or descalingFlush sediment from the bottom per manualDescale mineral buildup per manual, since scale can reduce flow
Anode rodInspect and replace when consumedNot applicable
Inlet filterNot typicalClean any screen filter the manual describes
Relief valve testTest yearlyTest per manual
VentingCheck the flue and draftCheck the vent and combustion air path
Expected life (DOE)10 to 15 yearsMore than 20 years

What to log each year

A written log turns maintenance into a record you can use. Keep it near the heater or in a note on your phone, and record the date, the thermostat setting, the measured tap temperature, whether you flushed the tank, the anode rod condition, the T&P test result, venting and burner notes, any leaks, and the date of the next check. A log also helps a pro diagnose problems faster and gives you the documentation that warranty claims often request.

When to bring in a pro and how to choose one

Some tasks are worth handing off: a T&P valve that will not seat or flow correctly, a jammed anode rod, soot or a yellow flame at a gas burner, a leak from the tank body, or a vent that needs rework. A tank that leaks from the body usually calls for replacement, not repair.

Get at least two written quotes before you agree to work. Check the contractor's license with the state licensing board where licensing applies, and ask who pulls the permits and whether the job requires one. Ask exactly what is included, such as haul-away of the old unit, any code upgrades, and warranty registration.

Frequently asked questions

How often should you flush a water heater?

Many manufacturers recommend flushing at least once a year. Your model's manual sets the exact schedule for flushing, anode checks and descaling, so follow it. If your water is hard or the tank runs with noise or reduced hot water, check the manual for guidance on whether you should flush more often. Keep a record of each flush so you can see patterns over time.

What temperature should a water heater be set to?

The U.S. Department of Energy and the Consumer Product Safety Commission both point to 120°F for most households. DOE notes that people with a compromised immune system or chronic respiratory disease may want to keep the tank at 140°F. In that case, a tempering valve set to 120°F at the outlet side of the tank lets the tank run hotter while the water at the tap stays at a safer temperature.

Can you test a T&P valve without draining the tank?

Yes. Place a bucket under the discharge pipe and lift the test lever briefly, then release it. Water should flow for a few seconds and stop. If the valve does not flow, or it keeps dripping after the test, the valve needs replacement. Never plug or cap the valve or its discharge pipe while you test it or afterward.

Does a tankless water heater need the same maintenance as a tank?

No, the tasks differ. Tankless units usually need descaling, and some have a screen filter to clean. There is no anode rod to inspect. Both types need a relief valve test, venting checks and a temperature check. DOE reports that tankless water heaters can last more than 20 years, but only with the maintenance their manuals describe.

How long does a water heater last with regular maintenance?

According to DOE, most storage tank water heaters last 10 to 15 years, and tankless water heaters can last more than 20 years. Regular maintenance helps a unit reach the upper part of its expected range by reducing sediment buildup, catching leaks early and keeping the safety valves working. It does not guarantee a specific lifespan, and a heater that shows repeated problems may need replacement.

Do you need a permit to replace a relief valve or discharge pipe?

It depends on your state and city. Some jurisdictions require a permit for work on water heater piping or safety devices, while others do not. Ask your local building department before starting the work, and ask whoever does the job who will pull any permit. Following the discharge pipe requirements in the International Plumbing Code and International Residential Code helps, but your local rules control.

Need a pro? See businesses that install and repair water heaters in your metro area. Ask for at least two written quotes and check the contractor's license with your state where it applies.