A water heater expansion tank is a small pressurized tank that absorbs extra water when heated water expands, keeping pressure in your plumbing from climbing too high. You usually need one when a check valve, pressure reducing valve or backflow preventer closes off the home's water supply, since expanding water then has nowhere to go.
What a water heater expansion tank does
Water takes up more space as it gets hotter. In an open plumbing system, some of that extra water pushes back toward the city main or well line without much change in pressure. In a closed system, where nothing lets water flow back out, the pressure rises every time the heater cycles on.
The expansion tank gives that extra water a place to go. Inside, a rubber bladder or diaphragm separates the water from a pocket of air. As the water expands, it pushes into the tank and compresses the air, which absorbs the added volume so the pressure stays within a safe range.
Why water expands in a closed system
This effect is called thermal expansion. It happens in any closed water system that is heated, including the hot water side of your home. The amount of pressure increase depends on the water temperature, the volume of the plumbing and how much water the system can release.
Thermal expansion is not a problem in every home. Plenty of houses with no backflow control devices never see a pressure spike, because the water main absorbs the expansion. The trouble starts when something stops that flow.
Check valves, pressure reducing valves and backflow preventers
A check valve lets water flow in only one direction. A pressure reducing valve (PRV) lowers the incoming pressure from the municipal line to a level suitable for the home. A backflow preventer stops water from returning to the public supply. All three can trap expanding water in your water heater and pipes.
Once one of these devices is in place, the pressure in the home can rise above the normal supply pressure each time the water heats. Over time, that stress can cause dripping at fittings, a slow leak at the heater, or fixtures that seem to work harder than they should. An expansion tank is the usual fix.
Check your home's plumbing layout. If you have a PRV or backflow preventer on the main line, expansion control is worth looking into. Check with your local building department to learn whether your area requires an expansion tank in that situation.
When you need an expansion tank
You are most likely to need one if any of these apply:
- The home has a PRV, check valve or backflow preventer on the main water line.
- The water heater or nearby fittings drip only when the heater is running, not when you run a tap.
- The temperature and pressure relief valve discharges water intermittently, especially during the night or when no one is using water.
- Faucets and showerheads sputter or spike in pressure after the heater kicks on.
- A plumber or inspector has recommended one during a replacement or remodel.
A tank that discharges through the relief valve regularly is a sign of a pressure problem. Do not assume the valve is faulty. Have the cause checked before you replace the valve or change anything in the system.
How to test an expansion tank for a failed bladder
A failed bladder is the most common reason an expansion tank stops working. Once the bladder ruptures or loses its air charge, the tank fills with water and can no longer absorb expansion. You can check the tank with a few basic steps.
Safety first: If your water heater is electric, turn off the breaker that powers it and confirm the power is off with a voltage tester before you touch the unit. For gas heaters, set the gas control to the off or pilot position and let the tank cool before working on it. Keep your hands clear of the relief valve discharge, since the water can be hot enough to cause serious scalding.
- Turn off the power or gas to the water heater and let the tank cool if it has been running.
- Shut off the cold water supply to the heater.
- Open a hot water tap nearby to release pressure, then close it.
- Remove the cap from the air valve on the top of the expansion tank. Press a tire-style pressure gauge onto the valve and read the air pressure.
- Compare that reading with the home's water pressure, measured with a gauge at an outdoor hose bib while no water is running. The air charge should be close to the home's static water pressure.
- Tap the outside of the tank with your knuckles. A solid, dull sound suggests the tank is full of water, which means the bladder has failed. A hollow sound suggests air is present.
- If the air pressure is very low, the valve does not hold air, or water comes out of the air valve when you press the gauge on, the tank needs replacement.
If the air charge is correct and the tank sounds hollow, the tank is probably working. Recheck the pressure if the relief valve keeps discharging, since the problem may lie elsewhere in the system.
Sizing and pre-charge pressure basics
Expansion tanks are sized to the volume of water in the heated system and the temperature rise the heater produces. A tank that is too small will fill quickly and fail to control pressure. A tank that is far too large is unnecessary but rarely causes trouble. The tank's label or the manufacturer's manual should list the sizing information you need.
Pre-charge refers to the air pressure in the tank before water enters it. It should match the home's static water pressure, which is the pressure in the system when no water is flowing. If the pre-charge is too low, the bladder can stretch and wear out early. If it is too high, the tank may not accept enough water to control expansion.
Set the pre-charge with the water supply off and the system at zero pressure. Use a gauge and a compressed air source, and check that the pressure matches your measured static pressure. Many homeowners pick the wrong sizing or pre-charge because they copy a tank from a neighbor's house, so measure your own system first.
Relief valve discharge and safety
The temperature and pressure relief valve on the water heater is the last line of defense if pressure or temperature gets too high. An expansion tank is meant to reduce how often that valve has to open. It does not replace the valve.
According to the International Code Council's summary of the International Plumbing Code and the International Residential Code (2021 editions), a relief valve discharge pipe must follow these rules:
- It must not connect directly to the drainage system.
- It must end in an air gap in the same room as the water heater.
- It must be no smaller than the valve outlet.
- It must not be trapped, and it must drain by gravity.
- It must end no more than 6 inches above the floor or a waste receptor.
- It must not have a threaded end, valves or tees.
- The pipe and valve assembly must be rated for 100 psi at 180°F.
A temperature and pressure relief valve must never be capped or plugged. If the valve discharges, find the cause rather than blocking the outlet. Plugging the valve removes the protection it provides.
The U.S. Department of Energy recommends setting your water heater to 120°F, which it describes as a temperature considered safe for most of the population. Lower settings reduce the risk of scalding at the tap. A tempering valve installed downstream of the tank can let the tank run hotter for disinfection while still delivering water at 120°F to the fixtures.
How to prevent expansion tank problems
Most expansion problems can be avoided with routine checks. Start with the basics:
- Check the air pressure in the expansion tank once a year, with the water supply off and the system depressurized.
- Watch for water around the base of the heater, the relief valve discharge or the expansion tank fittings.
- Keep the water heater flushed according to the manufacturer's manual. Many manufacturers recommend flushing at least once a year.
- Note when the relief valve discharges and whether it happens during periods of no water use.
- Keep records of the water heater installation, including the expansion tank size and the pre-charge setting.
Also consider the water heater's expected life. According to the U.S. Department of Energy, most storage (tank) water heaters last 10 to 15 years, while tankless water heaters can last more than 20 years. If your tank is near the end of that range and you have recurring pressure problems, replacing the heater and the expansion tank together can be more practical than repairing them separately.
When to call a professional
Some problems are straightforward to check, but others need a licensed plumber or qualified installer. Call for help if the relief valve discharges repeatedly, if you see water leaking from the tank body, if you smell gas, or if you are unsure how to isolate the water heater or set the pre-charge safely. Gas smell requires you to leave the home and call the gas utility or 911 from outside.
When you replace an expansion tank or add one, get at least two written quotes. Check the contractor's license with your state licensing board where licensing applies. Ask who pulls the permits, and ask what the quote includes, such as haul-away of the old tank, any code upgrades to the relief valve discharge pipe, and whether the warranty is registered for you.
Frequently asked questions
Does every water heater need an expansion tank?
No. Many homes do not need one because water can flow back to the supply and relieve pressure. An expansion tank becomes important when a check valve, PRV or backflow preventer closes the system. Check with your local building department to learn whether your jurisdiction requires one in your situation.
How can I tell if my expansion tank has gone bad?
Check the air pressure in the tank with the water supply off. Then tap the tank. A solid sound and low or missing air pressure usually means the bladder has failed. Repeated discharge from the relief valve or water spraying from the tank's air valve are also signs that the tank needs replacement.
What pressure should an expansion tank be set to?
The pre-charge should match your home's static water pressure, measured with a gauge at a hose bib when no water is running. Check the tank label and manufacturer's manual for any specific guidance. Set the pre-charge with the system depressurized, because a reading taken under pressure will not be accurate.
Can I remove the expansion tank if it keeps leaking?
Removing the tank without solving the pressure problem can cause the relief valve to discharge more often and stress the water heater and fittings. A leaking tank usually has a failed bladder and should be replaced. Find out why the tank is needed before you remove it, and check local rules about any change to the system.
Does an expansion tank replace the relief valve?
No. The temperature and pressure relief valve protects the water heater from dangerous conditions, and it must remain in place and unobstructed. An expansion tank only helps control pressure during normal heating. Never cap or plug the relief valve, and keep its discharge pipe installed according to the rules for that pipe.
What is the difference between an expansion tank and a pressure reducing valve?
A pressure reducing valve lowers the incoming pressure from the city or well supply to a level the home can use. An expansion tank absorbs the extra volume that heated water creates. A home with a PRV often needs an expansion tank too, because the PRV keeps water from flowing back out when it expands.