What temperature should a water heater be set to?

Set your water heater to 120°F. The U.S. Department of Energy calls that a temperature considered safe for most of the population, and it lowers scald risk at the tap. People with a compromised immune system or chronic respiratory disease may want to keep it at 140°F, so they should check with a doctor first.

Why 120°F is the usual starting point

The Consumer Product Safety Commission (CPSC) recommends setting water heaters to 120°F. According to the CPSC, third-degree burns can occur after about 2 seconds at 150°F, about 6 seconds at 140°F, and about 30 seconds at 130°F. Even 120°F can cause a third-degree burn after 5 minutes of exposure, so this setting lowers the risk without removing it.

The setting also affects energy use. According to the U.S. Department of Energy, water heating is about 18% of a home's energy use. A setting higher than you need means paying to heat water that often gets mixed with cold water at the faucet anyway.

When a higher setting may make sense

Some systems call for a hotter tank. The Department of Energy notes that Legionella can grow in water heaters under certain conditions, and a hotter tank can be part of managing that risk. Keeping the tank hot does not solve scald risk at the tap, though.

A tempering (mixing) valve installed downstream of the tank and set to 120°F lets the tank run hotter while limiting scald risk at faucets. Because installation affects plumbing and may require a permit, check with your local building department before adding one. Rules vary by state and city.

How to check and adjust the setting

Safety first: Hot water can scald within seconds at higher settings, and electric heaters carry shock risk. Turn off the breaker and verify there is no power before removing any electric access panel cover.

  1. Run the hot tap until the flow runs steadily, then fill a cup and measure the water with a thermometer.
  2. Find the control. Electric units usually have a thermostat behind an access panel on the side of the tank. Gas units have a dial on the gas control valve near the bottom, which may be labeled warm, hot or with numbers rather than degrees.
  3. Turn the dial in small steps. If you smell gas at any point, leave the home and call the gas utility or 911 from outside.
  4. Wait for the tank to reheat, then test the water at the tap again.
  5. Repeat until the tap reads about 120°F, and note the dial position for future reference.

Final checklist

  • Confirm the tap water measures about 120°F after the tank has reheated.
  • Check whether your system has a tempering valve, and confirm its setting if it does.
  • Make sure the temperature and pressure (T&P) relief valve is never capped or plugged.
  • Check that the relief valve discharge pipe does not connect directly to a drain and ends in an air gap in the same room.
  • Confirm the pipe is not smaller than the valve outlet, is not trapped, drains by gravity, and ends no more than 6 inches above the floor or a waste receptor.
  • Confirm the pipe has no threaded end, valves or tees. The International Plumbing Code 504.6 and International Residential Code P2804.6.1 (2021 editions, as summarized by the International Code Council) set these rules, and the relief valve should be rated for 100 psi at 180°F.
  • Follow the manufacturer's manual for flushing and anode inspection. Many manufacturers recommend flushing at least once a year.

If the setting, tempering valve or discharge pipe needs work, get at least two written quotes. Check the contractor's license with your state licensing board where licensing applies, ask who pulls permits, and ask what is included, such as haul-away, code upgrades and warranty registration.